117F ELECTRICANS DIGITAL MULTIMETER WITH NON-CONTACT VOLTAGE
117F ELECTRICANS DIGITAL MULTIMETER WITH NON-CONTACT VOLTAGE
$439.00
SUMMARY
Fluke 117 Electrician's Multimeter with Non-Contact voltage Designed by electricians. Engineered by Fluke. Compact...
DESCRIPTION
Fluke 117 Electrician's Multimeter with Non-Contact voltage
Designed by electricians. Engineered by Fluke.
Compact true-rms meter for commercial applications. TheFluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.
VoltAlert⢠technology for non-contact voltage detection AutoVolt automatic ac/dc voltage selection Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True-rms for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30-seconds) Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPakâ¢) for hands free operation CAT III 600 V safety rated Specifications Maximum voltage between any terminaland earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III,Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to 50 °C
Storage Temperature -40 °C to 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ( ): 0.5% 2
Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % 3 (dc, 45 Hz to 500 Hz) 4.0 % 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz) 2.0 % 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz) 2.0 % 3 (500 Hz to 1 kHz)
Continuity Range: 600 ⦠Resolution: 1 ⦠Accuracy: Beeper on 250 â¦; detects opens or shorts of 500 μs or longer.
AC amps true-rms (45 Hz to 500 Hz) Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.5% 3 20 A continuous overload for 30 seconds max
DC amps Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.0% 3 20 A continuous overload for 30 seconds max
Notes: 1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is specified from 0.0V. 2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
Mechanical & General Specifications Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")