117F ELECTRICANS DIGITAL MULTIMETER WITH NON-CONTACT VOLTAGE

$439.00
SUMMARY
Fluke 117 Electrician's Multimeter with Non-Contact voltage Designed by electricians. Engineered by Fluke. Compact...
DESCRIPTION
Fluke 117 Electrician's Multimeter with Non-Contact voltage

Designed by electricians. Engineered by Fluke.

Compact true-rms meter for commercial applications. TheFluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.

VoltAlert™ technology for non-contact voltage detection
AutoVolt automatic ac/dc voltage selection
Low input impedance: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True-rms for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30-seconds)
Resistance, continuity, frequency and capacitance
Min/Max/Average with elapsed time to record signal fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak™) for hands free operation
CAT III 600 V safety rated
Specifications
Maximum voltage between any terminaland earth ground
600 V

Surge protection
6 kV peak per IEC 61010-1 600 V CAT III,Pollution Degree 2

Fuse for A input
11 A, 1000 V FAST Fuse (Fluke PN 803293)

Display
Digital: 6,000 counts, updates 4 per second

Bar graph
33 segments, updates 32 per second

Operating Temperature
-10 °C to 50 °C

Storage Temperature
-40 °C to 60 °C

Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61

Battery Life
400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± (
): 0.5% 2

DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± (
): 0.5% 2

Auto volts
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 2.0 % 3 (dc, 45 Hz to 500 Hz)
4.0 % 3 (500 Hz to 1 kHz)

AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz)
2.0 % 3 (500 Hz to 1 kHz)

AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % 3 (dc, 45 Hz to 500 Hz)
2.0 % 3 (500 Hz to 1 kHz)

Continuity
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on 250 Ω; detects opens or shorts of 500 μs or longer.

Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 1.5 % 2

Diode Test
Range/Resolution: 2.000 V / 0.001 V
Accuracy: 0.9% 2

Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 μF / 0.01 μF
Range/Resolution: 100.0 μF / 0.1 μF
Range/Resolution: 9999 μF / 1 μF
Range/Resolution: 100 μF to 1000 μF
Accuracy: 1.9% 2
Range/Resolution: > 1000 μF
Accuracy: 5% 20%

LoZ capacitance
Range: 1 nF to 500 μF
Accuracy: 10% 2 typical

AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% 3
20 A continuous overload for 30 seconds max

DC amps
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% 3
20 A continuous overload for 30 seconds max

Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.99 Hz / 0.1 Hz
Range/Resolution: 9.999 Hz / 0.001 Hz
Range/Resolution: 50.00 Hz / 0.01 Hz
Accuracy: 0.1% 2

Notes:
1) All ac voltage ranges exept Auto - V / Lo-Z are specified from 1% to 100% of range. Auto - V / Lo-Z is specified from 0.0V.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.

Mechanical & General Specifications
Size
167 x 84 x 46 mm (6.57" x 3.31" x 1.82")

Weight
550 g

Warranty
3 years

Weight: 0.7390 kg