727 results
About this page

hot water system tripping power Page 25

If your hot water system keeps tripping the power, it’s usually an electrical gremlin rather than your house being haunted.

  • Failed heating element insulation: earth leakage trips the RCD the moment it warms up.
  • Thermostat or wiring fault: short or stuck-on control draws excess current and knocks the breaker.
  • Water ingress: leaks into junction boxes or the element cap cause nuisance trips, especially after rain.
  • Overloaded or tired circuit/RCD: undersized breaker, shared off-peak load, or a dying safety switch.

Isolate the HWS circuit, reset, and if it trips only with the heater on, book a licensed electrician (and plumber if it’s leaking) to test the element and thermostat, then replace the faulty bits.